Roof Smoke Hatch Inspection & Repair
Smoke and heat vents play a critical role in helping release smoke, heat, and toxic gases during a fire event. REMEDI8® performs annual inspections and operational testing of smoke and heat roof hatches to help confirm each unit opens, releases, and resets as intended.
Each hatch is documented by location with clear pass/fail results, photo support as needed, and prioritized next steps. Our inspection process helps facility teams identify damage, operational issues, blocked vents, worn components, failed parts, and missing documentation before they become larger compliance or safety concerns.
Each hatch is documented by location with clear pass/fail results, photo support as needed, and prioritized next steps. Our inspection process helps facility teams identify damage, operational issues, blocked vents, worn components, failed parts, and missing documentation before they become larger compliance or safety concerns.
Process
01
Comprehensive Visual Inspection
Inspect each smoke hatch for visible damage, obstruction, corrosion, wear, and overall condition.
02
Operational Testing
Verify that each unit opens, releases, and resets as intended.
03
Component Review
Check actuators, links, springs, hinges, covers, seals, and other key components for condition and wear.
04
Control and Release Function Review
Confirm manual release and automatic initiating components function as applicable.
05
Documentation and Reporting
Provide standardized, audit-ready reports by hatch location, including pass/fail status, photos, asset details, and recommended corrective actions.
06
Repair Support
Identify needed repairs and provide prioritized next steps to help restore proper operation and maintain compliance readiness.
Codes and Standards
NFPA 204
Smoke and heat venting systems must be tested and maintained to support proper operation during a fire event.
NFPA 101: Life Safety Code Life safety systems require inspection, maintenance, and documentation to support ongoing compliance and survey readiness.
IFC Section 910 Annual inspections help confirm smoke and heat vents are unobstructed, operational, and maintained as required.
NFPA 101: Life Safety Code Life safety systems require inspection, maintenance, and documentation to support ongoing compliance and survey readiness.
IFC Section 910 Annual inspections help confirm smoke and heat vents are unobstructed, operational, and maintained as required.
Why Choose REMEDI8®?
Compliance Support
Inspections aligned with NFPA 204, NFPA 101, and IFC Section 910 requirements.
Clear Documentation
Audit-ready reporting with pass/fail results, photos, asset tracking, and corrective action recommendations.
Inspection and Repair Expertise
Certified technicians help identify deficiencies and support repairs to keep smoke hatches operational and compliance-ready.